Welded Standard Accessories

Furnished With Tank
  • 3'8" x 6'8" walk-in door with a free air louver (skirted tank only)
  • Foundation anchor bolts and clips

Optional Accessories
  • Hillside flange in deck for mounting filter (size and weight required)
  • 20" diameter access in hopper or sidewall
  • 12" diameter aluminum slidegate with control handle
  • Stub and flanged nozzles in deck and sidewall
  • Openings for level indicator
  • 20" diameter manhole/ventilator in deck
  • 20" or 24" diameter dust-tight manhole in deck
  • 20" or 24" diameter combination manhole, pressure vacuum valve, (2 oz. pressure and 0.5 oz. vacuum). Recommended for use with filter.
  • 20" diameter hillside dome with cover for deck
  • Special hopper outlet opening
  • Deck perimeter guardrails with toeboard (OSHA), aluminum construction (alternate—hot-dip galvanized)
  • Outside ladders with safety enclosures and rest platforms (OSHA), hot-dip galvanized (alternate—aluminum construction)
  • Crossovers for use between tanks (OSHA), aluminum construction (alternate—hot-dip galvanized)

Bolted Standard Accessories

Furnished With Tank
  • 2' x 5' walk-in door in skirt below hopper
  • 20" center roof dome with cover plate
  • Foundation anchor bolts and saddles
  • Hardware and gasketing for assembly of tank

Optional Accessories
  • 3'-0" x 6'-8" walk-in door with a free air louver in lieu of standard 2" x 5" door
  • Hillside flange in deck for mounting filter (size and weight required)
  • Louvers for ventilation in skirt below hopper
  • 20" diameter access in hopper or sidewall
  • 12" diameter aluminum slidegate with control handle
  • Stub and flanged nozzles in deck and sidewall
  • Openings for level indicators
  • 20" diameter ventilator in deck
  • Plastic cap bolts
  • 20" diameter dust-tight manhole in deck
  • 20" or 24" diameter combination manhole, pressure vacuum valve, (2 oz. pressure and 0.5 oz. vacuum). Recommended for use with filter.
  • 20" diameter hillside dome with cover for deck
  • Special hopper outlet openings
  • Exterior push caps for nut protection
  • Deck perimeter guardrails with toeboard (OSHA)*
  • Outside ladders with safety enclosures and rest platforms (OSHA)*
  • Crossovers for use between tanks (2'–6", 4' 6' x 8' long) (OSHA)*
  • Spiral stairways (OSHA)*
  • Conveyor supports*

*Galvanized